{"product_id":"skutt-kilns-envirovent-2-kiln-vent","title":"Skutt EnviroVent 2:  Kiln Vent","description":"\u003ch2 class=\"abz-seo-product\"\u003e\n\u003cimg align=\"\" alt=\"\" border=\"0\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0677\/5508\/2050\/files\/dot1.gif?v=1684314273\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0677\/5508\/2050\/files\/dot1.gif?v=1684314273\"\u003eSKUTT KILNS EnviroVent 2 Ventilation System\u003c\/h2\u003e\n\u003cp\u003e\u003cimg align=\"right\" alt=\"\" border=\"0\" height=\"35\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0677\/5508\/2050\/files\/ev2_logo.gif?v=1684314290\" width=\"250\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0677\/5508\/2050\/files\/ev2_logo.gif?v=1684314290\" hspace=\"5\"\u003e\u003c\/p\u003e\n\u003cp\u003eDowndraft Ventilation System\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003ci\u003eSee PRODUCT VIDEOS tab for installation instruction video\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Skutt EnviroVent 2 requires a 120 Volt outlet.\u003c\/li\u003e\n\u003cli\u003eThe fan motor moves 140 cfm of air out of the room. Make sure you you consult with an HVAC professional to be sure the room is provided with adequate make-up air.\u003c\/li\u003e\n\u003cli\u003eThe EnviroVent® 2 comes with 8 ft. of 3 in. diameter, heavy duty, flexible aluminum ducting to go from the plenum cup to the vent motor. If more is needed to vent to the outside, you may order additional ducting from Skutt. Do not use thin walled dryer ducting.\u003c\/li\u003e\n\u003cli\u003eThe fan motor comes equipped with a 3 in. exhaust tube designed to pass through most walls and roofs. The maximum exiting temperature when installed correctly is 160 ºF.\u003c\/li\u003e\n\u003cli\u003eIf a vent is ordered with a kiln, the holes in the lid and slab are often drilled in the factory. If there are no holes drilled, consult the EnviroVent® 2 manual and drill the holes according to the recommendations for your model.\u003c\/li\u003e\n\u003cli\u003eIf you are venting a kiln between 12 cu\/ft and 24 cu\/ft you will need to use a Dual Intake Kit to draw air from 2 areas of the kiln. This kit may also be used to vent 2 kilns under 12 cu\/ft.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"bullet\"\u003e\u003cb\u003eVENT 2 KILNS With 1 MOTOR\u003c\/b\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"body\"\u003eNow you can vent 2 kilns with a single vent with the Skutt EnviroVent 2. The new 140 CFM Motor allows you to vent 2 kilns up to 12 Cubic Feet each, or one kiln between 12 and 24 Cubic Feet, with one Envirovent 2 Motor \u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"bullet\"\u003eWALL MOUNTED MEANS NO HEAT AND NO VIBRATION\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"body\"\u003eThe new design of the kiln ventilation system is wall mounted. This moves the vent motor away from under the kiln so the motor is no longer exposed to the heat and can no longer transfer any vibration into the kiln. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"bullet\"\u003e\u003cimg align=\"right\" alt=\"PLENUM CUP RETAINS SEAL THROUGHOUT FIRING\" border=\"0\" height=\"133\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0677\/5508\/2050\/files\/plenumseal.gif?v=1684314306\" width=\"167\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0677\/5508\/2050\/files\/plenumseal.gif?v=1684314306\"\u003eSPRING LOADED PLENUM CUP RETAINS SEAL THROUGHOUT FIRING\u003cspan class=\"body\"\u003e\u003cbr\u003eAs your kiln heats up the brick expands. When it expands the hot face of the kiln floor, the inside, expands more than the cold face or underside. This causes the slab to cup, or become slightly concave on the bottom. The result is that the center of the kiln floor moves upward at higher temperatures. The spring loaded cup follows the floor ensuring at tight seal throughout the firing process. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"bullet\"\u003eNEGATIVE PRESSURE MEANS NO LEAKING\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"body\"\u003eSince the Skutt EnviroVent 2 is wall mounted it pulls the air through the duct work instead of pushing it. This means if you were to ever form a leak in your duct work the fumes would not be pushed into the room. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"bullet\"\u003eABILITY TO CONTROL WITH KILNMASTER OR GLASS MASTER CONTROLLER\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"body\"\u003eNow with the purchase of the new Skutt EnviroLink you can control exactly when the Envirovent 2 turns on and off during a firing on a GlassMaster or KilnMaster kiln. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"body\"\u003e\u003cspan class=\"Ceramc_Subtitle\"\u003e\u003cimg align=\"left\" alt=\"EnviroVent 2 Kiln venting system\" border=\"0\" height=\"210\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0677\/5508\/2050\/files\/envirovent2.jpg?v=1684314322\" width=\"350\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0677\/5508\/2050\/files\/envirovent2.jpg?v=1684314322\" hspace=\"5\"\u003eSAME QUALITY VENTING\u003c\/span\u003e\u003cbr\u003eThe Skutt EnviroVent 2 is a Downdraft Ventilation System designed to extract fumes from your electric kiln and vent them outdoors before they have a chance to enter the room. Because it is a Downdraft Ventilation System, the\u003cbr\u003eEnviroVent 2 also improves the firing atmosphere in the kiln while it is protecting you from the odorous fumes that can be emitted from certain clay bodies and glazes when they are fired.\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"bullet\" style=\"font-style: italic;\" data-mce-style=\"font-style: italic;\"\u003e\u003cspan style=\"font-style: italic;\" data-mce-style=\"font-style: italic;\"\u003eHere's How It Works\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"body\"\u003eA designated number of holes are drilled in the lid and floor of the kiln either in the factory or on location. A spring loaded plenum cup (see diagram) is placed under the kiln and tensioned between the floor of the kiln and the floor under the kiln. The holes in the floor of the kiln are drilled in a tight pattern so the plenum cup can cover them all. The other end of the cup is connected by 3\" ducting to a fan which is generally mounted on the wall. On the opposite end of the fan the air is ducted through the wall to the outside air. The plenum cup has 3 additional holes from which it draws room temperature air to mix with the heated air from the kiln. This serves 2 purposes. Since the kiln air is mixed with cooler room air the air coming out of the end of the vent is never hotter than an average hair dryer. Secondly, the holes in the plenum cup are sized to reduce the vacuum on the kiln chamber so only a small amount of air is moving through the kiln. This ensures the firing time is not affected and the ware is not at risk. \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"bullet\" style=\"font-style: italic;\" data-mce-style=\"font-style: italic;\"\u003eBetter Heat Uniformity\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"body\"\u003eMost people are aware of the fact that heat rises. The Skutt EnviroVent 2 helps compensate for this rising heat by creating a flow of air moving back down the kiln chamber. As the air moves in a downward direction it is also deflected by ware and shelves causing turbulence. This turbulence helps move heat to cooler areas of the kiln like the center. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"bullet\" style=\"font-style: italic;\" data-mce-style=\"font-style: italic;\"\u003eBetter Kiln Atmosphere \u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"body\"\u003eWhen you are firing in an electric kiln you are firing in an Oxidation atmosphere. The EnviroVent 2 helps bring in more oxygen and flush out fumes which can form a reduction atmosphere. A reduction atmosphere can be desirable in a gas or wood fired kiln however it only causes problems in an electric kiln. Your elements will last longer, your glazes will be clearer and brighter and you will help prevent glazes migrating between pieces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg align=\"right\" alt=\"\" border=\"0\" height=\"212\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0677\/5508\/2050\/files\/envirovent2-illus_000dcd85-744e-460d-9ef4-b3bc2123b3ee.gif?v=1684314338\" width=\"375\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0677\/5508\/2050\/files\/envirovent2-illus_000dcd85-744e-460d-9ef4-b3bc2123b3ee.gif?v=1684314338\" hspace=\"5\" vspace=\"5\"\u003eBetter Working Environment\u003cbr\u003ePrior to the introduction of kiln ventilation systems it was still necessary to vent the kiln. This was done by propping the lid open with a wedge of brick until the kiln reached 1000°F (538 °C). Not only was this inconvenient, it also radiated the fumes right into the room.\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"bullet\" style=\"font-style: italic;\" data-mce-style=\"font-style: italic;\"\u003eA Better Vent \u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"body\"\u003eA new benefit of the EnviroVent 2 is that it is now a Negative Pressure System. This means that since the motor is pulling the air instead of pushing the air, if there is ever a hole in the ducting the fumes will not escape into the room. Also since the motor is now mounted away \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg align=\"\" alt=\"New EnviroLink\" border=\"0\" height=\"26\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0677\/5508\/2050\/files\/new_8fc072f7-d7e6-4f7e-8c3e-9029c370cb77.gif?v=1684314355\" width=\"36\"\u003eThe Skutt EnviroLink\u003cbr\u003eThe EnviroLink is an electrical switching device that can be controlled by an automatic kiln to determine when a vent turns on and off.\u003c\/p\u003e\n\u003cp\u003e\u003ci\u003eCertified safe.\u003c\/i\u003e\u003cbr\u003eThe Envirovent 2 is the only vent UL and c-UL listed to be used with Skutt Kilns.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: bold;\" data-mce-style=\"font-weight: bold;\"\u003e\u003cimg align=\"\" alt=\"\" border=\"0\" height=\"40\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0677\/5508\/2050\/files\/prod_specs.gif?v=1684314371\" width=\"149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0677\/5508\/2050\/files\/prod_specs.gif?v=1684314371\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"responsive-table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#f0f0f0\"\u003e\n\u003cdiv align=\"right\"\u003e\u003cspan style=\"font-weight: bold;\" data-mce-style=\"font-weight: bold;\"\u003e Motor: \u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd bgcolor=\"#f0f0f0\"\u003e120 volt\u003c\/td\u003e\n\u003ctd bgcolor=\"#f0f0f0\"\u003e1.4 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv align=\"right\"\u003e\u003cspan style=\"font-weight: bold;\" data-mce-style=\"font-weight: bold;\"\u003e Heat exiting blower: \u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e160° F maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#f0f0f0\"\u003e\n\u003cdiv align=\"right\"\u003e\u003cspan style=\"font-weight: bold;\" data-mce-style=\"font-weight: bold;\"\u003e Static pressure: \u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd bgcolor=\"#f0f0f0\" colspan=\"3\"\u003edistances greater than 60 ft: Use 4 inch ducting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv align=\"right\"\u003e\u003cspan style=\"font-weight: bold;\" data-mce-style=\"font-weight: bold;\"\u003e Blower \u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e140 cfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#f0f0f0\"\u003e\n\u003cdiv align=\"right\"\u003e\u003cspan style=\"font-weight: bold;\" data-mce-style=\"font-weight: bold;\"\u003eMaximum kiln capacity for use with EnviroVent 2: \u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd bgcolor=\"#f0f0f0\" colspan=\"3\"\u003eMaximum kiln capacity for use with EnviroVent2: 12 cubic feet (24 cubic feet with additional plenum cup kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Skutt","offers":[{"title":"Default Title","offer_id":45113815695682,"sku":"SKEV2","price":639.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0677\/5508\/2050\/files\/Untitleddesign_10.jpg?v=1697050854","url":"https:\/\/www.sheffield-pottery.live\/products\/skutt-kilns-envirovent-2-kiln-vent","provider":"Sheffield Pottery Inc.","version":"1.0","type":"link"}